Ethylparaben

Ethyl Paraben structural formula

CAS Number120-47-8
Molecular FormulaC9H10O3
Molecular Weight166.176
InChI KeyNUVBSKCKDOMJSU-UHFFFAOYSA-N
LogP2.47
Synonyms
  • Ethylparaben
  • Ethyl 4-hydroxybenzoate
  • Benzoic acid, 4-hydroxy-, ethyl ester
  • 120-47-8
  • ethyl 4-hydroxybenzoate
  • 4-10-00-00367
  • Benzoic acid, 4-hydroxy-, ethyl ester
  • 4-(Ethoxycarbonyl)phenol
  • 4-Carbethoxyphenol
  • 4-hidroxibenzoato de etilo
  • 4-Hydroxybenzoate d'ethyle
  • 4-HYDROXYBENZOESAEURE-AETHYLESTER
  • 4-Hydroxybenzoic acid ethyl ester
  • Aseptin A
  • Aseptine A
  • Aseptoform E
  • BENZOATE, 4-HYDROXY-, ETHYL
  • Benzoic acid, p-hydroxy-, ethyl ester
  • Bonomold OE
  • Easeptol
  • Ethyl Butex
  • Ethyl nipagin
  • Ethyl paraben
  • ETHYL PARASEPT
  • Ethyl p-hydroxybenzoate
  • Ethyl-4-hydroxybenzoat
  • Mekkings E
  • Mycocten
  • Napagin A
  • Nipagin A
  • Nipazin A
  • NSC 23514
  • NSC 8510
  • p-(Ethoxycarbonyl)phenol
  • p-Carbethoxyphenol
  • p-Hydroxybenzoate ethyl ester
  • p-Hydroxybenzoic acid ethyl ester
  • Sobrol A
  • Solbrol A
  • Tegosept E
  • BRN 1101972
  • Carbethoxyphenol
  • Caswell No. 447
  • EINECS 204-399-4
  • EPA Pesticide Chemical Code 061202
  • Ethyl p-oxybenzoate
  • Ester etylowykwasu p-hydroksybenzoesowego
  • Ethylester kyseliny p-hydroxybenzoove
  • p-Oxybenzoesaeureaethylester
  • UNII-14255EXE39

Applications:

HPLC Method for Estimation of Clotrimazole in Health Care Products on Primesep 200 Column

September 11, 2023

HPLC Method for Analysis of Clotrimazole, Benzyl alcohol, Ethylparaben on Primesep 200 by SIELC Technologies

HPLC Method for Analysis of Clotrimazole on Primesep 200 Column by SIELC Technologies
HPLC Method for Analysis of Clotrimazole, Benzyl alcohol, Ethylparaben on Primesep 200 by SIELC Technologies


 High Performance Liquid Chromatography (HPLC) Method for Analysis of  Clotrimazole, Benzyl alcohol, Ethylparaben

Clotrimazole is an antifungal medication widely used in the treatment of fungal infections.

Description:

  • Classification: Clotrimazole belongs to the class of medications called imidazole antifungals.

Uses:

  • Topical: It’s commonly used to treat skin infections such as athlete’s foot, jock itch, ringworm, and other fungal skin infections (candidiasis).
  • Vaginal: As a vaginal cream or tablet, it’s used to treat vaginal yeast infections.
  • Otic (Ear): Clotrimazole solution can be used to treat fungal ear infections.

Mechanism of Action:

  • Clotrimazole works by inhibiting the synthesis of ergosterol, a vital component of fungal cell membranes. When ergosterol synthesis is inhibited, it leads to structural and functional impairment of the fungal cell membrane, thereby killing the fungus or inhibiting its growth.

Clotrimazole belongs to the class of chemical compounds known as imidazoles. Specifically, it’s an antifungal compound used to treat fungal infections. Imidazoles work by inhibiting the enzyme lanosterol 14α-demethylase, which is necessary for the synthesis of ergosterol, an essential component of fungal cell membranes. When ergosterol synthesis is disrupted, it leads to alterations in the cell membrane’s permeability and, eventually, fungal cell death.

Other antifungal agents in the imidazole class include miconazole, econazole, and ketoconazole, among others. These are commonly used in various formulations to treat a range of fungal infections, including athlete’s foot, ringworm, and yeast infections.

Clotrimazole can be retained, and analyzed on a Primesep 200 mixed-mode stationary phase column using an isocratic analytical method with a simple mobile phase of water, Acetonitrile (MeCN), and a sulfuric acid as a buffer. This analysis method can be detected in the UV 200 nm.

ColumnPrimesep 200, 4.6 x 150 mm, 5 µm, 100 A
Mobile PhaseGradient MeCN – 40-90%, 10 min
BufferH2SO4 – 0.2%
Flow Rate1.0 ml/min
DetectionUV, 200 nm
Class of Compounds
Imidazole antifungals
Analyzing CompoundsClotrimazole, Benzyl alcohol, Ethylparaben

Application Column

Primesep 200

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A

Add to cart
Application Analytes:
Benzyl alcohol
Clotrimazole
Ethylparaben

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Analysis of Paraben Preservatives on Newcrom AH Column

October 29, 2020


HPLC.cloud
View on hplc.cloud

 

Condition

Column Newcrom AH, 3.2×100 mm, 5 µm, 100A
Mobile Phase MeCN/H2O – 30/70%
Buffer H2SO4 – 0.1%
Flow Rate 0.5 ml/min
Detection UV, 270 nm

 

Description

Class of Compounds
Preservatives,  Hydrophobic
Analyzing Compounds Methyl Paraben, Ethyl Paraben, Propyl Paraben

 

Application Column

Newcrom AH

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Ethylparaben
Methylparaben
Methylparaben sodium
Parabens
Propylparaben
Propylparaben sodium
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

Generic Screening Method for Complex Mixtures

October 15, 2015

Condition

Column Primesep 200, 4.6*150 mm 5 µm, 100A
Mobile Phase MeCN/H2O
Buffer H2SO4
Flow Rate 1.0 ml/min
Detection UV, 215 nm

 

Description

Class of Compounds
Drug, Acid, Hydrophilic, Ionizable, Hormone
Analyzing Compounds Uracil, Epinephrine, DOPA, 2,6-Lutidine, Benzylamine, Hydroxytrypthophan, Homovanillic acid, Phenol, Tryptophan , 2,3-DHBA, Benzoic acid, Methylparaben, Ethylparaben, Toluene, Amitriptyline

 

Application Column

Primesep 200

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
2,3-Dihydroxybenzoic Acid
2,6-Lutidine
Amitriptyline
Benzoic Acid
Benzylamine
DOPA (3,4-dihydroxy-L-phenylalanine)
Epinephrine
Ethylparaben
Homovanillic Acid
Hydroxytryptophan
Methylparaben
Phenol
Toluene
Tryptophan
Uracil

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Analysis of Active Drug and Amino Acids in a Formulation

October 14, 2010


Polar amino acids are very often used as components of vitamin and supplement composition. Analysis of such complex composition is a challenging task. In this application, 5 amino acids (asparagine, glutamic acid, proline and arginine) and two preservatives (methyl paraben and propyl paraben) are separated on a Primesep 100 reversed-phase cation-exchange column with LC/MS compatible mobile phase. Method does not require ion-pairing reagent in the mobile phase. Compounds are monitored by ELSD and UV. Method is validated for quantitation of underivatized amino acids in complex mixtures. The method is simple and robust and can be used for analysis of various vitamin formulations.

Condition

Column Primesep 100, 4.6×150 mm, 5 µm, 100A
Mobile Phase MeCN/H2O
Buffer AmFm
Flow Rate 1.0 ml/min
Detection ELSD 50C, UV 250 nm

 

Description

Class of Compounds
Drug, Acid, Hydrophilic, Ionizable, Vitamin, Supplements
Analyzing Compounds Glutamic acid, Aspargine,  Proline, Lysine, Arginine, Methyl paraben, Propyl paraben

 

Application Column

Primesep 100

The Primesep family of mixed-mode columns offers a wide variety of stationary phases, boasting unprecedented selectivity in the separation of a broad array of chemical compounds across multiple applications. Corresponding Primesep guard columns, available with all stationary phases, do not require holders. SIELC provides a method development service available to all customers. Inquire about our specially-tailored custom LC-phases for specific separations.

Select options
Application Analytes:
Arginine
Asparagine
Ethylparaben
Glutamic Acid
Lysine
Methylparaben
Proline

Application Detection:
ELSD Detection
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.