Terbutaline

Terbutaline structural formula

CAS Number23031-25-6
Molecular FormulaC12H19NO3
Molecular Weight225.288
InChI KeyXWTYSIMOBUGWOL-UHFFFAOYSA-N
LogP0.9
Synonyms
  • Terbutaline
  • 5-[2-(tert-Butylamino)-1-hydroxyethyl]benzene-1,3-diol
  • 1,3-Benzenediol, 5-[2-[(1,1-dimethylethyl)amino]-1-hydroxyethyl]-
  • 23031-25-6
  • 1,3-Benzenediol, 5-[2-[(1,1-dimethylethyl)amino]-1-hydroxyethyl]-
  • (.+-.)-Terbutaline
  • 1-(3, 5-Dihydroxyphenyl)-2-(t-butylamino) ethanol
  • 1-(3,5-Dihydroxyphenyl)-2-(tert-butylamino)ethanol
  • 5-[2-(1,1-Dimethylethyl)amino]-1-hydroxyethyl]-1,3-benzenediol
  • AR-D 080301
  • Benzyl alcohol, α-[(tert-butylamino)methyl]-3,5-dihydroxy-
  • Bricanyl
  • Bricaril
  • Terbutalin
  • terbutalino
  • BRN 2370513
  • 5-(2-((1,1-Dimethylethyl)amino)-1-hydroxyethyl)-1,3-benzenediol
  • EINECS 245-385-8
  • Terbutalina
  • Terbutalinum
  • UNII-N8ONU3L3PG

Applications:

UV-Vis Spectrum of Terbutaline

July 19, 2024

Access the UV-Vis Spectrum SIELC Library

UV-Vis Spectrum of Terbutaline. Absorption Maxima: 200 nm, 280 nm.

If you are looking for optimized HPLC method to analyze Terbutaline check our HPLC Applications library

For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can assist in selecting an appropriate wavelength for your analysis. Please note that certain mobile phases and buffers may block wavelengths below 230 nm, rendering absorbance measurement at these wavelengths ineffective. If detection below 230 nm is required, it is recommended to use acetonitrile and water as low UV-transparent mobile phases, with phosphoric acid and its salts, sulfuric acid, and TFA as buffers.
For some compounds, the UV-Vis Spectrum is affected by the pH of the mobile phase. The spectra presented here are measured with an acidic mobile phase that has a pH of 3 or lower.

Application Analytes:
Terbutaline
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Separation of Terbutaline Sulfate, Guaifenesin and Ambroxol on Primesep 200 Column

January 12, 2023

HPLC Method for Ambroxol Hydrochloride, Guaifenesin, Terbutaline, Ambroxol on Primesep 200 by SIELC Technologies

HPLC Method for Separation of Terbutaline Sulfate, Guaifenesin and Ambroxol on Primesep 200 Column
High Performance Liquid Chromatography (HPLC) Method for Analysis of Ambroxol Hydrochloride, Guaifenesin, Terbutaline, Ambroxol.

Terbutaline Sulfate is a salt form of Terbutaline, which is a β2 adrenergic receptor agonist with the chemical formula C12H19NO3. It is typically perscribed as an inhaler to assist with managing asthma symptoms as well as a tocolytic to relay preterm labor.. It is prohibited from use by the World Anti-Doping Agency without a Therapeutic Use Exemption (TUE) and is only allowed to be administered by inhalation. You can find detailed UV spectra of Terbutaline and information about its various lambda maxima by visiting the following link.

Guaifenesin, also known as glyceryl guaiacolate, is a drug with the chemical formula C10H14O4. It is used to remove sputum, or phlegm, from the respiratory tract. It works through stimulating the gastric mucosa, which leads to a higher volume and reduced viscosity of secretions in the trachea and the bronchi. You can find detailed UV spectra of Guaifenesin and information about its various lambda maxima by visiting the following link.

Ambroxol is a well-known expectorant with the chemical formula C13H18Br2N2O. It targets and breaks down phlegm through inhibiting neuronal Na+ channels. It also has anti-inflammatory properties. It has not yet been approved for use by the USA Food and Drug Administration. You can find detailed UV spectra of Ambroxol and information about its various lambda maxima by visiting the following link.

Together, these three medicinal compounds are typically found as the active ingredients in many cough syrups.

Ambroxol Hydrochloride, Guaifenesin, Terbutaline, Ambroxol can be retained and analyzed using the Primesep 200 stationary phase column. The analysis utilizes an isocratic method with a simple mobile phase consisting of water and acetonitrile (MeCN) with a phosphoric acid buffer. Detection is performed using UV. This analysis method can be detected in the low UV regime at 210 nm.

Condition

ColumnPrimesep 200, 4.6 x 150 mm, 5 µm, 100 A, dual ended
Mobile PhaseMeCN/H2O – 30/70%
BufferH3PO4 – 0.05%
Flow Rate1.0 ml/min
DetectionUV 210 nm
Peak Retention Time2.09, 3.28, 5.81 min

Description

Class of CompoundsDrugs
Analyzing CompoundsAmbroxol Hydrochloride, Guaifenesin, Terbutaline, Ambroxol

Application Column

Primesep 200

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
Ambroxol
Ambroxol Hydrochloride
Guaifenesin
Terbutaline

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Separation of Guaifenesin and Terbutaline on Primesep 200

June 5, 2006

Application Column

Primesep 200

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
Guaifenesin
Terbutaline

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Separation of Guaifenesin and Terbutaline on Primesep 100

June 5, 2006

Application Column

Primesep 100

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
Guaifenesin
Terbutaline

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.