| CAS Number | 23031-25-6 |
|---|---|
| Molecular Formula | C12H19NO3 |
| Molecular Weight | 225.288 |
| InChI Key | XWTYSIMOBUGWOL-UHFFFAOYSA-N |
| LogP | 0.9 |
| Synonyms |
|
Applications:
UV-Vis Spectrum of Terbutaline
July 19, 2024
Access the UV-Vis Spectrum SIELC Library
UV-Vis Spectrum of Terbutaline. Absorption Maxima: 200 nm, 280 nm.
If you are looking for optimized HPLC method to analyze Terbutaline check our HPLC Applications library
For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can assist in selecting an appropriate wavelength for your analysis. Please note that certain mobile phases and buffers may block wavelengths below 230 nm, rendering absorbance measurement at these wavelengths ineffective. If detection below 230 nm is required, it is recommended to use acetonitrile and water as low UV-transparent mobile phases, with phosphoric acid and its salts, sulfuric acid, and TFA as buffers.
For some compounds, the UV-Vis Spectrum is affected by the pH of the mobile phase. The spectra presented here are measured with an acidic mobile phase that has a pH of 3 or lower.
HPLC Method for Separation of Terbutaline Sulfate, Guaifenesin and Ambroxol on Primesep 200 Column
January 12, 2023
HPLC Method for Ambroxol Hydrochloride, Guaifenesin, Terbutaline, Ambroxol on Primesep 200 by SIELC Technologies

Terbutaline Sulfate is a salt form of Terbutaline, which is a β2 adrenergic receptor agonist with the chemical formula C12H19NO3. It is typically perscribed as an inhaler to assist with managing asthma symptoms as well as a tocolytic to relay preterm labor.. It is prohibited from use by the World Anti-Doping Agency without a Therapeutic Use Exemption (TUE) and is only allowed to be administered by inhalation. You can find detailed UV spectra of Terbutaline and information about its various lambda maxima by visiting the following link.
Guaifenesin, also known as glyceryl guaiacolate, is a drug with the chemical formula C10H14O4. It is used to remove sputum, or phlegm, from the respiratory tract. It works through stimulating the gastric mucosa, which leads to a higher volume and reduced viscosity of secretions in the trachea and the bronchi. You can find detailed UV spectra of Guaifenesin and information about its various lambda maxima by visiting the following link.
Ambroxol is a well-known expectorant with the chemical formula C13H18Br2N2O. It targets and breaks down phlegm through inhibiting neuronal Na+ channels. It also has anti-inflammatory properties. It has not yet been approved for use by the USA Food and Drug Administration. You can find detailed UV spectra of Ambroxol and information about its various lambda maxima by visiting the following link.
Together, these three medicinal compounds are typically found as the active ingredients in many cough syrups.
Ambroxol Hydrochloride, Guaifenesin, Terbutaline, Ambroxol can be retained and analyzed using the Primesep 200 stationary phase column. The analysis utilizes an isocratic method with a simple mobile phase consisting of water and acetonitrile (MeCN) with a phosphoric acid buffer. Detection is performed using UV. This analysis method can be detected in the low UV regime at 210 nm.
Condition
| Column | Primesep 200, 4.6 x 150 mm, 5 µm, 100 A, dual ended |
| Mobile Phase | MeCN/H2O – 30/70% |
| Buffer | H3PO4 – 0.05% |
| Flow Rate | 1.0 ml/min |
| Detection | UV 210 nm |
| Peak Retention Time | 2.09, 3.28, 5.81 min |
Description
| Class of Compounds | Drugs |
| Analyzing Compounds | Ambroxol Hydrochloride, Guaifenesin, Terbutaline, Ambroxol |
Application Column
Primesep 200
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended
Ambroxol Hydrochloride
Guaifenesin
Terbutaline
HPLC Separation of Guaifenesin and Terbutaline on Primesep 200
June 5, 2006

Application Column
Primesep 200
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended
Terbutaline
HPLC Separation of Guaifenesin and Terbutaline on Primesep 100
June 5, 2006

Application Column
Primesep 100
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended
Terbutaline