Perfluorobutyric Acid (PFBA)

CAS Number375-22-4
Molecular FormulaC4HF7O2
Molecular Weight214.04
InChI KeyYPJUNDFVDDCYIH-UHFFFAOYSA-N
LogP2.2
Synonyms
  • Heptafluorobutyric acid
  • 375-22-4
  • Perfluorobutyric acid
  • Perfluorobutanoic acid
  • Heptafluorobutanoic acid
  • Butanoic acid, heptafluoro-
  • Heptafluoro-1-butanoic acid
  • Perfluoropropanecarboxylic acid
  • 2,2,3,3,4,4,4-Heptafluorobutanoic acid
  • BUTYRIC ACID, HEPTAFLUORO-
  • Kyselina heptafluormaselna
  • NSC 820
  • YPJUNDFVDDCYIH-UHFFFAOYSA-N
  • Kyselina heptafluormaselna [Czech]
  • heptafluoro-butanoic acid
  • EINECS 206-786-3
  • Butanoic acid, 2,2,3,3,4,4,4-heptafluoro-
  • Heptafluoro-n-butyric acid
  • BRN 1426882
  • UNII-12VHZ8L29I
  • 12VHZ8L29I
  • CHEBI:39426
  • Heptafluorobutyric acid, 99%
  • Heptafluorobutyric acid, 99%, for protein sequence analysis
  • Heptafluorobutyricacid
  • heptaflurorbutyric acid
  • PubChem12664
  • heptafluoro-butyric acid
  • ACMC-209udx
  • n-heptafluorobutyric acid

Applications:

Uv-Vis Spectrum of Perfluorobutyric Acid 

October 1, 2026

Access the UV-Vis Spectrum SIELC Library

If you are looking for optimized HPLC method to analyze Perfluorobutyric Acid (PFBA) check our HPLC Applications library

UV/Vis.: λmax: 190 nm

For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can assist in selecting an appropriate wavelength for your analysis. Please note that certain mobile phases and buffers may block wavelengths below 230 nm, rendering absorbance measurement at these wavelengths ineffective. If detection below 230 nm is required, it is recommended to use acetonitrile and water as low UV-transparent mobile phases, with phosphoric acid and its salts, sulfuric acid, and TFA as buffers.
For some compounds, the UV-Vis Spectrum is affected by the pH of the mobile phase. This compound was diluted in a mixture of water and acetonitrile. The method was done with a mixture of water and acetonitrile.

 

 

 

 

 

 

Application Analytes:
Perfluorobutyric Acid (PFBA)
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Separation of Perfluoroalkyl Acids PFBA, PFAO, PEAS on Newcrom A Column

July 21, 2020

HPLC Method for Perfluorobutyric Acid (PFBA), Perfluorooctylsulfonic acid (PFAS), Perfluorooctanoic acid (PFOA) on Newcrom A by SIELC Technologies

High Performance Liquid Chromatography (HPLC) Method for Analysis of Perfluorobutyric Acid (PFBA), Perfluorooctylsulfonic acid (PFAS), Perfluorooctanoic acid (PFOA).

Perfluoroalkyl acids (PFAAs) such as Perfluorobutyric acid, Perfluorononanoic acid and Perfluorooctylsulfonic acid are contaminants that have increasingly been found in groundwater and drinking water systems.
Perfluoroalkyl acids (PFAAs) are also strong surfactants that have been used industrially, in the production of fluoropolymers, but they are also present as residual impurities in a wide range of polymeric consumer products e.g. used to impart water and stain repellency in textiles, papers, and boards.
We were able to separate Perfluoroalkyl acids (PFAAs) in HPLC on Newcrom A mixed-mode column using a mobile phase of acetonitrile (ACN), and water with Ammonium Formate buffer. This separation can be monitored with ELSD, CAD detection techniques.

Condition

Column Newcrom A, 4.6 x 150 mm, 5 µm, 100 A, dual ended
Mobile Phase MeCN – 40%
Buffer AmFm pH 3.0 – 50 mM
Flow Rate 1.0 ml/min
Detection CAD

Description

Class of Compounds Perfluoroalkyl acids
Analyzing Compounds Perfluorobutyric Acid (PFBA), Perfluorooctylsulfonic acid (PFAS), Perfluorooctanoic acid (PFOA)

 

Application Column

Newcrom A

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
Perfluorobutyric Acid (PFBA)
Perfluorooctanoic acid (PFOA)
Perfluorooctylsulfonic acid (PFAS)

Application Detection:
CAD Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.