Molnupiravir (EIDD-2801, MK-4482)

CAS Number2492423-29-5
Molecular Formula C13H19N3O7
Molecular Weight329.31
InChI KeyHTNPEHXGEKVIHG-QCNRFFRDSA-N
LogP-0.8
Synonyms
  • EIDD 2801
  • EIDD-2801
  • EIDD2801
  • molnupiravir
  • 2349386-89-4
  • MK-4482
  • UNII-YA84KI1VEW
  • YA84KI1VEW
  • Eidd 1931-isopropyl ester
  • 2492423-29-5
  • Molnupiravir [USAN]
  • ((2R,3S,4R,5R)-3,4-Dihydroxy-5-(4-(hydroxyimino)-2-oxo-3,4-dihydropyrimidin-1(2H)-yl)tetrahydrofuran-2-yl)methyl isobutyrate
  • [(2R,3S,4R,5R)-3,4-dihydroxy-5-[4-(hydroxyamino)-2-oxopyrimidin-1-yl]oxolan-2-yl]methyl 2-methylpropanoate
  • WHO 11853
  • ((2R,3S,4R,5R)-3,4-Dihydroxy-5-(4-(hydroxyamino)-2-oxopyrimidin-1(2H)-yl)tetrahydrofuran-2-yl)methyl isobutyrate
  • molnupiravirum
  • Lagevrio
  • Molnupiravir [INN]
  • Molnupiravir [WHO-DD]
  • pro-EIDD-1931
  • EIDD-2801(Molnupiravir)
  • Uridine, 4-oxime, 5'-(2-methylpropanoate), (4Z)-
  • CHEMBL4650320
  • EIDD 1931 5'-isopropylester
  • GTPL10737
  • med.21724, Compound 182
  • CHEBI:180653

Applications:

Uv-Vis Spectrum of Molnupiravir

January 12, 2026
Access the UV-Vis Spectrum SIELC Library
UV-Vis Spectrum of Molnupiravir (EIDD-2801, MK-4482).

If you are looking for optimized HPLC method to analyze Molnupiravir (EIDD-2801, MK-4482) check our HPLC Applications library

For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can assist in selecting an appropriate wavelength for your analysis. Please note that certain mobile phases and buffers may block wavelengths below 230 nm, rendering absorbance measurement at these wavelengths ineffective. If detection below 230 nm is required, it is recommended to use acetonitrile and water as low UV-transparent mobile phases, with phosphoric acid and its salts, sulfuric acid, and TFA as buffers.
For some compounds, the UV-Vis Spectrum is affected by the pH of the mobile phase. The spectra presented here are measured with an acidic mobile phase that has a pH of 3 or lower.

 

 

Application Analytes:
Molnupiravir (EIDD-2801, MK-4482)
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Analysis of Molnupiravir on Newcrom R1 Column

June 15, 2022

HPLC Method for Molnupiravir (EIDD-2801, MK-4482) on Newcrom R1 by SIELC Technologies

High Performance Liquid Chromatography (HPLC) Method for Analysis of Molnupiravir (EIDD-2801, MK-4482).

Molnupiravir is an antiviral drug with the chemical formula C13H19N3O7. It works through inhibiting RNA replication in viruses like influenza and ebola. It gained recent notoriety in its ability to help treat COVID-19 infections from the SARS-CoV-2 virus. You can find detailed UV spectra of Molnupiravir (EIDD-2801, MK-4482) and information about its various lambda maxima by visiting the following link.

Molnupiravir (EIDD-2801, MK-4482) can be retained and analyzed using the Newcrom R1 stationary phase column. The analysis utilizes an isocratic method with a simple mobile phase consisting of water and acetonitrile (MeCN). Detection is performed using UV.  This analysis method can be UV detected at 235 nm with high resolution and peak symmetry.

Condition

Column Newcrom R1, 3.2 x 100 mm, 5 µm, 100 A, dual ended
Mobile Phase MeCN -15%
Buffer No
Flow Rate 0.5 ml/min
Detection UV 235nm

Description

Class of Compounds Drug
Analyzing Compounds Molnupiravir (EIDD-2801, MK-4482)

 

Application Column

Newcrom R1

Column Diameter: 3.2 mm
Column Length: 100 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended

Add to cart
Application Analytes:
Molnupiravir (EIDD-2801, MK-4482)

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.