Polyhexanide PHMB

CAS Number28757-47-3
Molecular Formula C8H19N5
Molecular Weight185.27
InChI KeyVAZJLPXFVQHDFB-UHFFFAOYSA-N
LogP0.5
Synonyms
  • Polyhexanide
  • Polyhexamethylene biguanide
  • n-hexylbiguanide
  • 1-Hexylbiguanide
  • POLYXEDININE
  • AC1L2HDF
  • SCHEMBL45011
  • CHEMBL2106939
  • SCHEMBL20753163
  • DTXSID40873856
  • N-Hexylimidodicarbonimidic diamide
  • VAZJLPXFVQHDFB-UHFFFAOYSA-N
  • ZINC4217340
  • AKOS017531707
  • VZ36849
  • 1-(diaminomethylidene)-2-hexylguanidine
  • FT-0700841
  • 24717-31-5

Applications:

HPLC Method for Separation Alexidine and Polyhexanide on BIST B+ Column

January 23, 2024

High Performance Liquid Chromatography (HPLC) Method for Analysis of Polyhexanide PHMB, Alexidine on BIST B+ by SIELC Technologies

Separation type: Bridge Ion Separation Technology, or BIST™ by SIELC Technologies

HPLC Method for Separation Alexidine and Polyhexanide on BIST B+ Column
HPLC Method for Analysis of Polyhexanide PHMB, Alexidine on on BIST B+ by SIELC Technologies

Alexidine and polyhexanide are both antiseptic agents used for various applications, particularly in the field of medicine and healthcare.

  1. Alexidine:
    • Usage: Alexidine is a bisbiguanide antiseptic that is often used in oral care products, such as mouthwashes and dental formulations.
    • Antimicrobial Properties: It has broad-spectrum antimicrobial properties, effective against bacteria, fungi, and some viruses.
    • Application: Alexidine has been studied for its use in controlling oral biofilm and preventing dental plaque.
  2. Polyhexanide:
    • Usage: Polyhexanide is a polymeric biguanide antiseptic that is used in various medical applications, including wound care and disinfection.
    • Antimicrobial Properties: Similar to alexidine, polyhexanide has broad-spectrum antimicrobial properties and is effective against bacteria, fungi, and some viruses.
    • Application: Polyhexanide is commonly used as an antiseptic solution for wound irrigation and for the treatment of infected wounds. It can also be found in some contact lens solutions.

Both alexidine and polyhexanide belong to the biguanide class of antiseptics, and they are known for their effectiveness against a wide range of microorganisms. The specific applications and formulations may vary based on the intended use, and these agents are often used in healthcare settings to prevent infections.

Alexidine and polyhexanide can be retained, separated and analyzed on a BIST B+ mixed-mode stationary phase column using an analytical method with a simple mobile phase of water, Acetonitrile (MeCN) , and a sulfuric acid as a buffer. This analysis method can be detected using UV at 200 nm.

High Performance Liquid Chromatography (HPLC) Method for Analyses of Polyhexanide PHMB, Alexidine

Condition

ColumnBIST B+, 4.6 x 150 mm, 5 µm, 100 A
Mobile Phase*Step Gradient
  A: MeCN – 75%, H2SO4 – 0.1% / 3 min
  B: MeCN – 0%, H2SO4 – 0.1% / 6 min
Buffe H2SO4 -0.1%
Flow Rate1.0 ml/min
DetectionUV 200 nm
Sample 1.  0.14 mg/ml
2.  0.26 mg/ml
LOD **8 ppb, 10 ppb
Injection volume10 µl

*The step gradient methods involve sudden changes in the solvent composition of the mobile phase, resulting in the baseline’s instability. It is necessary to account for this response to be able to interpret, integrate, and process results adequately. The blank sample (sample diluent) has to be analyzed before injecting the sample of interest. When all chromatograms are generated, it is necessary to subtract the blank chromatogram from the sample one before the integration step.

**LOD was determined for this combination of instrument, method, and analyte, and it can vary from one laboratory to another even when the same general type of analysis is being performed

Description

Class of CompoundsBis-biguanide
Analyzing CompoundsPolyhexanide PHMB, Alexidine

Application Column

BIST B+

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A

Add to cart
Application Analytes:
Alexidine
Polyhexanide PHMB

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Method for Analysis of Polyhexanide (polyhexamethylene biguanide, PHMB) on BIST B+

November 30, 2022

HPLC Method forAnalysis of Polyhexanide (polyhexamethylene biguanide, PHMB) on BIST B+ by SIELC Technologies.

Separation type: Bridge Ion Separation Technology, or BIST™ by SIELC Technologies

Analysis of Polyhexanide (polyhexamethylene biguanide, PHMB)
HPLC Method for Analysis of Polyhexanide (polyhexamethylene biguanide, PHMB) on BIST B+ by SIELC Technologies.

High Performance Liquid Chromatography (HPLC) Method for Analyses of Polyhexanide (polyhexamethylene biguanide, PHMB)

Polyhexanide (polyhexamethylene biguanide, PHMB) has multiple industrial, medical, biological and research applications. It has strong antiseptic properties that make this compound very useful for materials that could be a possible source of bacterial contamination.  Using SIELC’s newly introduced BIST™ method, Polyhexanide (polyhexamethylene biguanide, PHMB) can be retained on a positively-charged anion-exchange BIST™ B+ column. 

There are two keys to this retention method: 1) a multi-charged, negative buffer, such as Sulfuric acid (H2SO4), which acts as a bridge, linking the positively-charged analytes to the positively-charged column surface and 2) a mobile phase consisting of a majority of organic solvent (such as MeCN) to minimize the formation of a solvation layer around the charged analytes. Utilizing a step gradient to switch to a completely aqueous MP after 2 minutes allows for retention to occur while also preventing the method from being too long. Using this new and unique analysis method, PHMB can be separated, retained, and UV detected at 200 nm.


Condition

ColumnBIST B+, 4.6×50 mm, 5 µm, 100A
Mobile PhaseMeCN Step gradient
BufferH2SO4 – 0.2%
Flow Rate1.0 ml/min
DetectionUV 200 nm
Peak Retention Time3.3 min

Description

Class of CompoundsPolymers
Analyzing CompoundsPolyhexanide (polyhexamethylene biguanide, PHMB)

Application Column

BIST B+

BIST™ columns offer a unique and effective way to achieve separations that were traditionally challenging or even impossible with other HPLC columns. With the use of a special mobile phase, these ion exchange columns provide very strong retention for analytes with the same charge polarity as the stationary phase, unlocking new chromatography applications. What makes BIST™ columns stand out is their proprietary surface chemistry, which results in superior selectivity, resolution, and sensitivity. These columns offer a simple, efficient solution for a variety of analytical challenges, making them an excellent choice for researchers and analysts across many different fields. To learn more about the technology that powers BIST™ columns and to explore related applications, check out https://BIST.LC.

Select options
Application Analytes:
Polyhexanide PHMB
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Determination of Polyhexanide (PHMB) on PEI Column

September 26, 2019


 

Polyhexanide (polyhexamethylene biguanide, PHMB) is a polymer used as a disinfectant and antiseptic. We estimated that limit of detection is about 2 ppm for this compounds with this method.

The peak of polyhexanide fractionated on several peaks due to difference in length of the polymer components.

 

Condition

Column PEI , 4.6×250 mm, 5 µm, 100A
Mobile Phase MeCN/H2O – 40/60%
Buffer AmFm pH 3.0- 20 mM
Flow Rate 0.5 ml/min
Detection UV, 236 nm

 

Description

Class of Compounds
Polymer, Hydrophilic, Ionizable, Antiseptic, Disinfectant
Analyzing Compounds Polyhexanide (PHMB)

 

Application Column

PEI

SIELC Technologies offers custom phases for customers who require specific separations not achievable with commercially available HPLC phases. Considering the vast array of compounds and mixtures requiring analysis, tailored LC phases can significantly enhance separation results for unique and challenging applications. To learn more about our special custom LC phases designed for your specific separation needs, please contact SIELC Technologies at research@sielc.com. Our team of experts is ready to guide you through the process and create a custom solution that addresses your particular chromatographic challenges.

Select options
Application Analytes:
Polyhexanide PHMB
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.