Pentachlorophenol

Pentachlorophenol structural formula

CAS Number87-86-5
Molecular FormulaC6HCl5O
Molecular Weight266.321
InChI KeyIZUPBVBPLAPZRR-UHFFFAOYSA-N
LogP5.12
Synonyms
  • Pentachlorophenol
  • Phenol, 2,3,4,5,6-pentachloro-
  • 87-86-5
  • PCP
  • 2,3,4,5,6-Pentachlorophenol
  • Phenol, pentachloro-
  • 1-Hydroxy-2,3,4,5,6-pentachlorobenzene
  • 1-Hydroxypentachlorobenzene
  • Chlorophenasic acid
  • CHLOROPHENATE
  • Dowicide EC 7
  • Dura Treet II
  • Fungifen
  • Grundier Arbezol
  • Lauxtol
  • Liroprem
  • NSC 263497
  • Penchlorol
  • Pentachlorphenol
  • Perchlorophenol
  • Permasan
  • Phenol, 2,3,4,5,6-pentachloro-
  • Pole topper
  • Pole topper fluid
  • Preventol P
  • Santophen 20
  • Satophen
  • UN 3155
  • Witophen P
  • Woodtreat A
  • BRN 1285380
  • Caswell No. 641
  • Chem-Penta
  • Dow pentachlorophenol DP-2 antimicrobial
  • Dowicide 7 Antimicrobial
  • Dowicide EC-7
  • EINECS 201-778-6
  • EPA Pesticide Chemical Code 063001
  • Forpen-50 Wood Preservative
  • NCI-C54933
  • NCI-C55378
  • NCI-C56655
  • Ontrack WE Herbicide
  • Ortho Triox Liquid Vegetation Killer
  • Osmose Wood Preserving Compound
  • Penta Concentrate
  • Penta ready
  • Penta WR
  • Pentachlorofenol
  • Pentachlorophenol, DP-2
  • Permatox DP-2
  • Permatox penta
  • RCRA waste number U242
  • Watershed Wood Preservative
  • Weed and Brush Killer
  • Pentachloorfenol
  • Pentaclorofenolo
  • UNII-D9BSU0SE4T
  • 2, 3,4,5,6-Pentachlorophenol
  • 2,3,4,5,6-Pentachlorophenol (ACD/Name 4.0)
  • Chem-Tol
  • Chlorophen
  • Dowicide 7
  • Dowicide G
  • Durotox
  • Fungifen
  • Glazd penta
  • Lauxtol A
  • PCP (pesticide)
  • Penta
  • Penta-Kil
  • Pentachloorfenol (DUTCH)
  • Pentachloro-Phenol
  • Pentachlorophenate
  • Pentachlorophenol pure
  • Pentachlorphenol (GERMAN)
  • Pentaclorofenolo (ITALIAN)
  • Pentacon
  • Pentasol
  • Penwar
  • Peratox
  • Permacide
  • Permagard
  • Permatox
  • Permite
  • Phenol, pentachloro-, pure
  • Santobrite
  • Santophen
  • Sinituho
  • Term-i-trol
  • Thompson'S wood fix
  • Weedone
  • 101802-54-4
  • 1135443-67-2
  • 39390-77-7

Applications:

HPLC Separation of Haloaromatics and Quinones on Newcrom B Column

February 6, 2020


HPLC.cloud
View on hplc.cloud

 

 

Condition

Column Newcrom B, 4.6×150 mm, 3 µm, 100A
Mobile Phase MeCN/H2O – 55/45%
Buffer H3PO4 – 0.1%
Flow Rate 1.0 ml/min
Detection UV 200 nm

 

Description

Class of Compounds Haloaromatics, Quinones, Hydrophobic
Analyzing Compounds 1,4-benzoquinone, 1,4-hydroquinone, Chloranil (Tetrachloro-1,4-benzoquinone), Chlorothalonil, Tetrachlorohydroquinone, Pentachlorophenol

Application Column

Newcrom B

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Benzoquinone
Chloranil
Chlorothalonil
Hydroquinone
Pentachlorophenol
Tetrachlorohydroquinone
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Separation of Pesticides on Newcrom B Column

February 3, 2020

Condition

Column Newcrom B, 4.6×150 mm, 3 µm, 100A
Mobile Phase MeCN/H2O
Buffer Formic Acid
Flow Rate 1.0 ml/min
Detection UV, 260, 270 nm

Description

Class of Compounds Hydrophobic, Herbicide, Pesticide
Analyzing Compounds Metalaxyl, Propoxur, Paclobutrazol, Abamectin, Propanil, Iprodione,  Dursban, Pentachlorophenol, Fenvalerate

Application Column

Newcrom B

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Abamectin
Chlorpyrifos-methyl (Dursban)
Fenvalerate
Iprodione
Metalaxyl
Paclobutrazol
Pentachlorophenol
Propanil
Propoxur
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

HPLC Separation of 12 Pesticides on Newcrom B Column

January 24, 2020


HPLC.cloud
View on hplc.cloud

 

Condition

Column Newcrom B, 4.6×150 mm, 5 µm, 100A
Mobile Phase MeCN/H2O
Buffer Formic Acid
Flow Rate 1.0 ml/min
Detection UV, 260 nm

Description

Class of Compounds Hydrophobic, Herbicide, Pesticide
Analyzing Compounds 6-Benzylaminopurine, Metalaxyl, Prochloraz, Paclobutrazol, Procymidone, Propanil, Chlorothalonil, Abamectin, Bifenazate, Dursban, Pentachlorophenol, Fenvalerate

Application Column

Newcrom B

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
6-Benzylaminopurine
Abamectin
Bifenazate
Chlorothalonil
Chlorpyrifos-methyl (Dursban)
Fenvalerate
Metalaxyl
Paclobutrazol
Pentachlorophenol
Prochloraz
Procymidone
Propanil
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.

Separation of Pentachlorophenol on Newcrom R1 HPLC column

February 19, 2018
Separation of Pentachlorophenol on Newcrom C18 HPLC column

Pentachlorophenol can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Pentachlorophenol
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.