CAS Number | 1197-18-8 |
---|---|
Molecular Formula | C8H15NO2 |
Molecular Weight | 157.213 |
InChI Key | GYDJEQRTZSCIOI-UHFFFAOYSA-N |
LogP | -0.894 |
Synonyms |
|
Applications:
HPLC – MS Method for Analysis of Tranexamic acid on Primesep 100 Column
December 20, 2023
HPLC Method for Analysis of Tranexamic acid on Primesep 100 by SIELC Technologies
High Performance Liquid Chromatography (HPLC) Method for Analysis of Tranexamic acid
Tranexamic acid is a medication with significant roles in medicine, primarily used to treat or prevent excessive bleeding.
Chemical Structure: Tranexamic acid (TXA) is a synthetic derivative of the amino acid lysine. Its chemical formula is C8H15NO2. The structure features a lysine molecule with its amino group transformed into an amide.
Mechanism of Action: Tranexamic acid works by inhibiting the activation of plasminogen to plasmin, a molecule responsible for breaking down fibrin clots. By preventing the formation of plasmin, TXA reduces the breakdown of clots, thereby controlling bleeding.
Tranexamic acid is a valuable medication in controlling excessive bleeding in various medical contexts. Its use is supported by substantial research, particularly in emergency and surgical settings, though it must be used with consideration for its potential side effects and contraindications.
Tranexamic acid can be retained and analyzed on a Primesep 100 mixed-mode stationary phase column using an isocratic analytical method with a simple mobile phase of water, Acetonitrile (MeCN), and a ammonium format as a buffer. This analysis method can be detected an Evaporative Light Scattering Detector (ELSD), or any other evaporative detection method (CAD, ESI-MS)
Column | Primesep 100, 2.1 x 100 mm, 5 µm, 100 A |
Mobile Phase | MeCN – 20%, |
Buffer | Ammonium Formate pH 3.0-50 mM |
Flow Rate | 0.2 ml/min |
Detection | SIM 158 + |
LOD* | 0.2 ppm |
Spray Voltage: | 1.5 kV |
Nebulizing gas: | 1.5 L/min |
Drying gas: | 15 L/min |
DL temp: | 250 ˚C |
Heat Block: | 400 ˚C |
Class of Compounds | Amino acid |
Analyzing Compounds | Tranexamic acid |
Application Column
Primesep 100
Column Diameter: 2.1 mm
Column Length: 100 mm
Particle Size: 5 µm
Pore Size: 100 A
HPLC Determination of Tranexamic acid (TXA) on Primesep 100 Column
July 2, 2021
HPLC Method for Analysis of Tranexamic acid on Primesep 100 by SIELC Technologies
Separation type: Liquid Chromatography Mixed-mode
Tranexamic acid (TXA) is a synthetic derivative of the amino acid lysine. It is a medication used to treat or prevent excessive blood loss from major trauma, surgery, tooth removal, nosebleeds, and heavy menstruation. It is also used for hereditary angioedema. It can be taken by mouth, injected into a vein, or applied topically.
Tranexamic acid works by inhibiting the activation of plasminogen to plasmin, an enzyme that degrades fibrin clots, fibrinogen, and other proteins in the extracellular matrix. By inhibiting the activation of plasmin, tranexamic acid stabilizes clots and reduces bleeding.
Tranexamic acid can be retained on a Primesep 100 mixed-mode column with embedded acidic ion-pairing groups, having great peak shape using an isocratic method of acetonitrile (ACN), water and perchloric acid (HClO4) as a buffer. UV Detection 210nm.
High Performance Liquid Chromatography (HPLC) Method for Analysis of Tranexamic acid
Column | Primesep 100, 4.6 x 150 mm, 5 µm, 100 A |
Mobile Phase | MeCN/H2O – 20/80% |
Buffer | HClO4 – 0.2% |
Flow Rate | 1.0 ml/min |
Detection | UV 210 nm |
Class of Compounds | Acid, Drug |
Analyzing Compounds | Tranexamic acid |
Application Column
Primesep 100
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
HPLC Determination of Tranexamic acid (TXA) on Primesep 200 Column
June 23, 2021
HPLC Method for Analysis of Tranexamic acid on Primesep 200 by SIELC Technologies
High Performance Liquid Chromatography (HPLC) Method for Analysis of Tranexamic acid.
Tranexamic acid is a synthetic derivative of the amino acid lysine. Tranexamic acid is an antifibrinolytic agent. It works by blocking the breakdown of blood clots, which prevents bleeding. Tranexamic acid can be retained on a Primesep 200 mixed-mode column with embedded weak acidic ion-pairing groups, having great peak shape using an isocratic method of acetonitrile (ACN), water and perchloric acid (H3PO4) as a buffer. UV Detection 210nm.
Column | Primesep 200, 4.6 x 150 mm, 5 µm, 100 A |
Mobile Phase | MeCN/H2O – 5/95% |
Buffer | H3PO4 – 0.1% |
Flow Rate | 1.0 ml/min |
Detection | UV 210 nm |
Class of Compounds | Acid, Drug |
Analyzing Compounds | Tranexamic acid |
Application Column
Primesep 200
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Separation of Tranexamic acid on Newcrom R1 HPLC column
February 16, 2018
Tranexamic acid can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.
Application Column
Newcrom R1
The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.
Select options